﻿{"id":14280,"date":"2019-11-01T18:32:59","date_gmt":"2019-11-01T17:32:59","guid":{"rendered":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/?p=14280"},"modified":"2024-01-09T19:13:53","modified_gmt":"2024-01-09T18:13:53","slug":"oscilloscope-tektronix-type-565-serial-689-seventh-part","status":"publish","type":"post","link":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/oscilloscope-tektronix-type-565-serial-689-seventh-part\/","title":{"rendered":"Oscilloscope Tektronix Type 565 serial 689, fifth part ( MITI Muesum)"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14282\" src=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-5-FRONT-Osc.Tek_.565.jpg\" alt=\"\" width=\"1500\" height=\"1372\" srcset=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-5-FRONT-Osc.Tek_.565.jpg 1500w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-5-FRONT-Osc.Tek_.565-300x274.jpg 300w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-5-FRONT-Osc.Tek_.565-768x702.jpg 768w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-5-FRONT-Osc.Tek_.565-1024x937.jpg 1024w\" sizes=\"(max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14283\" src=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-6-FRONT.DESC_.-Osc.Tek_.565.jpg\" alt=\"\" width=\"844\" height=\"1500\" srcset=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-6-FRONT.DESC_.-Osc.Tek_.565.jpg 844w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-6-FRONT.DESC_.-Osc.Tek_.565-169x300.jpg 169w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-6-FRONT.DESC_.-Osc.Tek_.565-768x1365.jpg 768w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/6-6-FRONT.DESC_.-Osc.Tek_.565-576x1024.jpg 576w\" sizes=\"(max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><span style=\"font-family: 'times new roman', times, serif;\">Oscilloscopio Tektronix Type 565. Quinta parte. <\/span><br \/>\n<span style=\"font-family: 'times new roman', times, serif;\">Nell\u2019inventario D del 1956 si trova al n\u00b0 3747 e risulta acquistato nell\u2019agosto del 1964; vi si legge: \u201cSilvestar ltd. Milano. Oscilloscopio Tektronix mod. 565 matr. 689. Dest. Elettronica \u20a4 1<sup>\u0387<\/sup>678<sup>\u0387<\/sup>600\u201d. Insieme alla fotocamera che \u00e8 al n\u00b0 3746, dove si legge: \u201cSilvestar ltd. Milano. Macchina fotografica Tektronix mod. C-12 completa di Bezel-Tektronix. Dest. Elettronica. \u20a4 557<sup>\u0387<\/sup>700\u201d.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Il testo continua dalla quarta parte.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">\u00a7\u00a7\u00a7<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>\u00abDEMONSTRATION 1<\/strong>: Measuring time between two pulses, <\/span><span style=\"font-family: 'times new roman', times, serif;\">the first of which triggers Time Base <\/span><span style=\"font-family: 'times new roman', times, serif;\">\u2018A\u2019.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u00a0 \u00a0 \u00a0 Set the controls and switches on the instrument as <\/span><span style=\"font-family: 'times new roman', times, serif;\">listed above except as follows;<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u2018A\u2019 TIME\/DIV.\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0.1 mSEC<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u2018B\u2019 TIME\/DIV.\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a01 \u03bcSEC<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\"> Apply the Amplitude Calibrator signal to the input of <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">both vertical plug-in units. The Upper Beam should display <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">about one cycle of the squarewave signal.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Set the DELAY INTERVAL dial so the falling portion of<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">the squarewave\u00a0 is intensified. Advance the Lower Beam<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">INTENSITY control to obtain a display of normal intensity.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The Lower Beam should now display a horizontally<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">expanded version of the signal in the intensified segment of <\/span><span style=\"font-family: 'times new roman', times, serif;\">the Upper Beam display.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Set DELAY INTERVAL so the Lower Beam trace starts at<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">About\u00a0 the 50% amplitude level of the squarewave. Multiply <\/span><span style=\"font-family: 'times new roman', times, serif;\">the DELAY INTERVAL dial reading (e.g. 5.13) by the \u2018A\u2019 <\/span><span style=\"font-family: 'times new roman', times, serif;\">sweep rate. The product is the time duration of the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">squarewave positive-going half-cycle.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>Accuracy<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Accuracy is determined by the combination of all the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">following factors;<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">1. The basic accuracy of the Time Base Generator, and<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">therefore, of time measurements, is \u00b13%. In measurements<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">made directly from the crt, this means \u00b13% of full <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">scale; that is, of the total time represented within the 10 <\/span><span style=\"font-family: 'times new roman', times, serif;\">major graticule divisions. However, when the measurement <\/span><span style=\"font-family: 'times new roman', times, serif;\">is made by using the sweep delay feature, the accuracy <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">is \u00b13\u00b0\/, of reading; that is, of the time being measured.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 NOTE<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">During calibration, the internal DELAY START and <\/span><span style=\"font-family: 'times new roman', times, serif;\">DELAY STOP adjustments are set when the Time <\/span><span style=\"font-family: 'times new roman', times, serif;\">Base \u2018A\u2019 sweep rate is 1 mSEC per division. Therefore, <\/span><span style=\"font-family: 'times new roman', times, serif;\">delay measurements made when using the<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">1 mSEC per division \u2018A\u2019 sweep rate will generally <\/span><span style=\"font-family: 'times new roman', times, serif;\">be most accurate. The delay accuracy obtained <\/span><span style=\"font-family: 'times new roman', times, serif;\">at any other \u2018A\u2019 sweep rate, 10 \u03bcseconds per <\/span><span style=\"font-family: 'times new roman', times, serif;\">division or slower, can be increased by calibrating<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">DELAY START and DELAY STOP at that sweep <\/span><span style=\"font-family: 'times new roman', times, serif;\">rate. (In so doing, you may wish to verify that <\/span><span style=\"font-family: 'times new roman', times, serif;\">all other \u2018A\u2019 sweep rates produce delays that are <\/span><span style=\"font-family: 'times new roman', times, serif;\">accurate within 3%). These adjustments do not <\/span><span style=\"font-family: 'times new roman', times, serif;\">affect the Time Base \u2018A\u2019 crt sweep rate. See the <\/span><span style=\"font-family: 'times new roman', times, serif;\">Calibration Procedure, Section 5, step 10.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">2. The effect that the linearity of the Delay Interval <\/span><span style=\"font-family: 'times new roman', times, serif;\">system has on the measurement accuracy depends on the <\/span><span style=\"font-family: 'times new roman', times, serif;\">DELAY INTERVAL dial setting that is used. The linearity <\/span><span style=\"font-family: 'times new roman', times, serif;\">factor, as a percentage of reading, decreases as the dial <\/span><span style=\"font-family: 'times new roman', times, serif;\">setting increases. With any dial setting, the inaccuracy due <\/span><span style=\"font-family: 'times new roman', times, serif;\">to non-linearity will not exceed 0.5% of full scale delay.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">3. Measurements are valid only when DELAY INTERVAL <\/span><span style=\"font-family: 'times new roman', times, serif;\">dial settings above 0.50 are used.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">4. The triggering point can affect the measurement<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">accuracy since the triggering signal does not rise in zero<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">time. For example, if the sweep is triggered by the first<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">portion of the pulse rise, most of the pulse risetime will be<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">included in the measurement. This is of little concern in<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">measurements, such as the one made in Demonstration 1,<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">where the risetime of the signal is a relatively insignificant<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">percentage of the time being measured. However, as the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">risetime percentage of the measured time increases, it<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">becomes more important that the triggering point be known.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">One way to establish a known triggering point is to set the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">LEVEL control at one end of the range in which a stable,<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">triggered Upper Beam display is obtained. Most of the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">risetime of the signal will be included in the measurement<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">when:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">a. \u2018A\u2019 TRIGGER SLOPE is set to + and LEVEL is set to<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">the \u2014 end of the &#8220;triggering&#8221; range (positive-going<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">signals), or<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">b. \u2018A\u2019 TRIGGER SLOPE is set to &#8211; and LEVEL is set to<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">the + end of the \u201ctriggering\u201d range (negative-going <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">signals).<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">5. The Time Base \u2018A\u2019 Trigger, Time Base \u2018A\u2019 Generator,<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Delay Pickoff, and Time Base \u2018B\u2019 Generator circuits typically <\/span><span style=\"font-family: 'times new roman', times, serif;\">require a total of about 1.0 to 1.5 microseconds to respond <\/span><span style=\"font-family: 'times new roman', times, serif;\">to the signal event which triggers Time Base \u2018A\u2019. This small <\/span><span style=\"font-family: 'times new roman', times, serif;\">delay need not be considered unless it is a significant <\/span><span style=\"font-family: 'times new roman', times, serif;\">percentage of the time being measured. When necessary, add <\/span><span style=\"font-family: 'times new roman', times, serif;\">the circuit delay time to the measured time.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">6. The 5, 2, and 1 \u03bcSEC\/DIV A sweep rates generally are<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">not used for measurements such as those described in<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Demonstration 1.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>Summary<\/strong>\u2014The method described in Demonstration 1 will<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">provide greatest time measurement accuracy when:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">a. the internal DELAY START and DELAY STOP adjustments <\/span><span style=\"font-family: 'times new roman', times, serif;\">are calibrated at the sweep rate to be used,<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">b. dial settings above 4.0 or 5.0 are used,<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">c. the event triggering Time Base \u2018A\u2019 has a fast rise time,<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">and<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">d. Time Base \u2018A&#8217; sweep rates of 50 \u03bcSEC\/DIV. or slower<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">are used.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>DEMONSTRATION 2<\/strong>: Measuring time between two pulses <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">of a pulse train, neither of which triggers Time Base \u2018A\u2019.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Set the controls and switches on the instrument as listed<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">except as follows:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">\u2018A\u2019 TIME\/DIV.\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0.2 mSEC<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Apply the Amplitude Calibrator signal to the input of\u00a0 <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">both vertical plug-in units. The Upper Beam should display <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">about two cycles of the squarewave signal. Set the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">DELAY INTERVAL dial so the squarewave rise located near <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">the center of the Upper Beam display is intensified.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Advance the Lower Beam INTENSITY control to obtain<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">a display of normal intensity. The Lower Beam should now<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">display a horizontally expanded version of the intensified<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Upper Beam display segment.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Set DELAY INTERVAL so the 50% amplitude level of the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">squarewave rise intersects the vertical line at the center <\/span><span style=\"font-family: 'times new roman', times, serif;\">of the graticule. Note the exact DELAY INTERVAL dial <\/span><span style=\"font-family: 'times new roman', times, serif;\">setting (e.g. 5.14). Turn the DELAY INTERVAL dial clockwise <\/span><span style=\"font-family: 'times new roman', times, serif;\">until the 50% amplitude level of the squarewave fall <\/span><span style=\"font-family: 'times new roman', times, serif;\">intersects the same vertical graticule line used with the previous <\/span><span style=\"font-family: 'times new roman', times, serif;\">dial setting. Again note the exact DELAY INTERVAL dial <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">setting.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Subtract the first dial setting from the second. The <\/span><span style=\"font-family: 'times new roman', times, serif;\">product of this difference and the Time Base \u2018A\u2019 TIME\/DIV. <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">equals the time duration of the squarewave positive-going <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">half-cycle (between the 50% amplitude points).<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>Accuracy<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif;\">Accuracy is determined by the combination of all the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">following factors:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">1. The basic accuracy of the Time Base \u2018A\u2019 generator is <\/span><span style=\"font-family: 'times new roman', times, serif;\">the same as described in Demonstration 1.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">2. The percentage of error that the Delay Interval system <\/span><span style=\"font-family: 'times new roman', times, serif;\">linearity adds to the measurement depends on the numerical<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">difference between the two dial settings used; this error<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">decreases as the numerical difference increases. The amount <\/span><span style=\"font-family: 'times new roman', times, serif;\">of time error in the measurement is less than 1% of the full<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">scale delay (1%, of ten times the &#8216;A&#8217; sweep TIME\/DIV.).<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">However, this applies only when the DELAY INTERVAL dial <\/span><span style=\"font-family: 'times new roman', times, serif;\">settings are separated by at least 100 minor dial divisions.<\/span><span style=\"font-family: 'times new roman', times, serif;\"><br \/>\nNOTE<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">When the separation between dial settings is <\/span><span style=\"font-family: 'times new roman', times, serif;\">one hundred minor dial divisions or less, the <\/span><span style=\"font-family: 'times new roman', times, serif;\">desired time measurement can often be made more<\/span><span style=\"font-family: 'times new roman', times, serif;\"> accurately by direct reading from a magnified <\/span><span style=\"font-family: 'times new roman', times, serif;\">crt display. See Demonstration 3; Magnification.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">3. Measurements are valid only when DELAY INTERVAL<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">dial settings above 0.50 are used.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">4. The accuracy of time measurements made according <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">to Demonstration 2 is independent of the inherent circuit <\/span><span style=\"font-family: 'times new roman', times, serif;\">delays and of the triggering point (discussed in <\/span><span style=\"font-family: 'times new roman', times, serif;\">Demonstration 1), provided the \u2018A\u2019 LEVEL control setting <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">is the same <\/span><span style=\"font-family: 'times new roman', times, serif;\">for each of the two dial readings.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">5. The 2 and 1 \u03bcSEC\/DIV. A sweep rates generally are <\/span><span style=\"font-family: 'times new roman', times, serif;\">not used in measurements such as those described in <\/span><span style=\"font-family: 'times new roman', times, serif;\">Demonstration 2.<br \/>\n<\/span><strong style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Summary<\/strong><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">\u2014 The method described in Demonstration 2 can<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">provide a time measurement accuracy within 1% of reading.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u00a0Accuracy will be greatest when:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">a. the internal DELAY START and DELAY STOP<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">adjustments are calibrated at the sweep rate to be used, and<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">b.the numerical difference between the two DELAY <\/span><span style=\"font-family: 'times new roman', times, serif;\">INTERVAL dial settings is greatest.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>DEMONSTRATION 3<\/strong>: Magnification<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Complex signals often consist of a number of individual<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">events of different amplitudes. Since the trigger circuits<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">of the Type 565 are sensitive to signal amplitude, a stable<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">display will normally be obtained only when the sweep <\/span><span style=\"font-family: 'times new roman', times, serif;\">is triggered by the event having the greatest amplitude.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The \u201cStarts After Delay Interval\u201d mode permits the start <\/span><span style=\"font-family: 'times new roman', times, serif;\">of a sweep to be delayed for a selected time after the <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">signal event having the greatest amplitude.\u00a0 Any event <\/span><span style=\"font-family: 'times new roman', times, serif;\">within the series of events may then be displayed in <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">magnified form as follows:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Set the controls and switches on the Type 565 as listed. <\/span><span style=\"font-family: 'times new roman', times, serif;\">Apply the Amplitude Calibrator signal to the input of both<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">vertical plug-in units. The Upper Beam should display<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">several cycles of the squarewave signal. Set the DELAY<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">INTERVAL dial to intensify one of the positive-going pulses.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Advance the Lower Beam INTENSITY control to obtain<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">a display of normal intensity. The Lower Beam display<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">should now contain the same signal information as the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">intensified Upper Beam trace segment, but horizontally<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">expanded (magnified) ten times.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Increase the Time Base \u2018B\u2019 sweep rate to 1 microsecond<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">per division. Set the DELAY INTERVAL dial so the intensified <\/span><span style=\"font-family: 'times new roman', times, serif;\">segment in the Upper Beam trace extends throughout\u00a0 the <\/span><span style=\"font-family: 'times new roman', times, serif;\">rise of one of the positive-going pulses. The Lower Beam <\/span><span style=\"font-family: 'times new roman', times, serif;\">display now gives X1000 magnification.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Slowly turn the DELAY INTERVAL dial. Note that any<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">portion of the Upper Beam display can be brought into <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">view in magnified form on the Lower Beam display (except <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">for a small portion at the beginning and end of the Upper <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Beam Display). The DELAY INTERVAL dial indication <\/span><span style=\"font-family: 'times new roman', times, serif;\">corresponds to the number of major graticule divisions<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">between the beginning of the Upper Beam trace and the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">beginning of the intensified trace segment; e.g. 7.00 = 7<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">major divisions.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Set the Time Base \u2018B&#8217; sweep rate to 10 microseconds per <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">division. Set the DELAY INTERVAL dial so a squarewave<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">rise is centered in the Lower Beam display. Set UPPER<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">HORIZ. DISPLAY to \u2018B\u2019 TIME BASE and turn on the Upper <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Beam IOX MAG. Set the Upper Beam horizontal POSITION <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">so the squarewave rise is visible in the Upper Beam display.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">The Lower Beam now gives 100 times magnification<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">and the Upper Beam gives 1000 times magnification of the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">information that was contained in the intensified segment <\/span><span style=\"font-family: 'times new roman', times, serif;\">of the original Upper Beam display.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Both the Upper and Lower Beam display will probably<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">exhibit some horizontal jitter. Part of the jitter is due to a<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">slight inconsistency in the Amplitude Calibrated signal<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">frequency, and part is due to jitter in the delay system. The <\/span><span style=\"font-family: 'times new roman', times, serif;\">jitter contributed by the delay system is less than 0.05%<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">of the Time Base \u2018A\u2018 sweep rate (0.05% of 1 millisecond<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"> = 0.5 microsecond). With 1000 times magnification, the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Upper Beam sweep rate is 1 microsecond per division.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Hence, the jitter due to the delay system is less than <\/span><span style=\"font-family: 'times new roman', times, serif;\">one-half major division.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>Accuracy<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif;\">1. The accuracy of time measurements made from<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">magnified displays such as those described in the foregoing<br \/>\npara<\/span><span style=\"font-family: 'times new roman', times, serif;\">graphs, depend solely on the Time Base \u2018B\u2018 sweep rate<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">accuracy (\u00b13%, with the 10X MAG. off and \u00b15 with the10X MAG. on).<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>DEMONSTRATION 4<\/strong>: Delayed Trigger<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Ordinarily, a signal which is to be displayed is also used <\/span><span style=\"font-family: 'times new roman', times, serif;\">to trigger the oscilloscope sweeps so a stable display is <\/span><span style=\"font-family: 'times new roman', times, serif;\">obtained. In some situations, it may be desirable to <\/span><span style=\"font-family: 'times new roman', times, serif;\">reverse this situation. The sweep-related output pulses, <\/span><span style=\"font-family: 'times new roman', times, serif;\">available at the rear panel of the Type 565, can be used* as <\/span><span style=\"font-family: 'times new roman', times, serif;\">the input or triggering signals for external devices. The <\/span><span style=\"font-family: 'times new roman', times, serif;\">output signal of the external device will then produce a <\/span><span style=\"font-family: 'times new roman', times, serif;\">stable display while the oscilloscope sweep free-runs.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">To demonstrate one method of performing this operation,<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">proceed as follows:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Set the controls and switches on the Type 565 as listed<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">except as follows;<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u2018A\u2019 TRIGGER source\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 EXT.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u2018A\u2019 TRIGGER COUPLING\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 DC<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">\u2018A\u2019 TIME\/DIV.\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 10 \u03bcSEC<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">\u2018B\u2019 MODE\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0NORMAL TRIGGER<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">\u2018B\u2019 TRIGGER LEVEL\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 FREE RUN<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">DELAY INTERVAL\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 1.00<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">INTENSITY (Upper)\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0normal<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\"> Connect: (rear panel and front panel connections)<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u2018B\u2019 + GATE OUT\u00a0\u00a0\u00a0\u00a0 \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0to\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u2018A\u2019 TRIG. IN<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">DEL&#8217;D TRIG. OUT\u00a0\u00a0 \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0to\u00a0\u00a0\u00a0\u00a0\u00a0 INPUT of the Upper Beam plug-in unit<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"> Set \u2018A\u2019 TRIGGER LEVEL mid-way between \u2018O\u2019 and FREE<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">RUN so Time Base \u2018A\u2019 triggers on the rise of the \u2018B\u2019 + GATE<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">OUT signal. The Upper Beam should now display a narrow,<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">positive-going pulse.<br \/>\n<\/span><\/p>\n<hr \/>\n<p><strong style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\"><span style=\"font-size: 14pt;\">*Output current must not exceed 2 ma peak.<br \/>\n<\/span><br \/>\n<\/strong><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">The oscilloscope display that you have established shows <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">a pulse that is available from the Type 565 during each Time <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Base \u2018A\u2019 sweep. In a practical application, the pulse would<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">not be applied to the vertical input of the oscilloscope, but<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">instead to some external device to be tested. The pulse would <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">serve as the trigger pulse for the external device and the <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">output of the device would be displayed on the oscilloscope.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Since the pulse has a known time-relationship to<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">each Time Base \u2018A\u2019 sweep, the output of the device will<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">provide a stable display on the oscilloscope, as though <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">the oscilloscope were triggered in the normal manner.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">The set-up described in the foregoing paragraphs permits <\/span><span style=\"font-family: 'times new roman', times, serif;\">you to vary the repetition rate of the pulse applied to the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">external device. To do this, monitor the pulse signal on <\/span><span style=\"font-family: 'times new roman', times, serif;\">another oscilloscope and set &#8216;B&#8217; TIME\/DIV. and VARIABLE <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">for the desired repetition rate. \u2018A\u2019 TIME\/DIV. controls only <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">the display sweep rate as long as the Time Base \u2018A\u2019 Sweep <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">rate is at least twice that of Time Base \u2018B\u2019.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Set &#8216;B&#8217; MODE to MANUAL TRIGGER and press the MANUAL <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">TRIGGER push-button. This set-up permits you to <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">produce each DEL&#8217;D TRIG. OUT pulse manually.<br \/>\n<\/span><strong style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">DEMONSTRATION 5<\/strong><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">: Pulse Generation <\/span><span style=\"font-family: 'times new roman', times, serif;\">The \u2018B\u2019 + GATE OUT signal of the Type 565 can be used <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">as a low-current*, variable repetition rate, variable duty<\/span><span style=\"font-family: 'times new roman', times, serif;\">factor pulse generator in applications where the pulse shape <\/span><span style=\"font-family: 'times new roman', times, serif;\">is of secondary importance. To use the Type 565 in this <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">manner, proceed as follows:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Set<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\"> UPPER HORIZ. DISPLAY\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u2018A\u2019 TIME BASE<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"> LOWER HORIZ. DISPLAY\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u2018B\u2019 TIME BASE<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u2018B\u2019 MODE\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0STARTS AFTER DELAY <\/span><span style=\"font-family: 'times new roman', times, serif;\">INTERVAL<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"> DELAY INTERVAL\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0about 0.50<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">LEVEL\u00a0 (\u2018A\u2019 and \u2018B\u2019)\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 FREE RUN<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The pulse signal is available at the \u2018B\u2019 + GATE OUT<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">connector on the rear panel. Monitor the signal on another<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">oscilloscope and establish the desired pulse repetition rate by <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">setting the Type 565 &#8216;A&#8217; TIME\/DIV. and VARIABLE. Establish <\/span><span style=\"font-family: 'times new roman', times, serif;\">the desired duty factor by setting \u2018B\u2019 TIME\/DIV.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The maximum pulse repetition frequency that can be<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">obtained in this manner is about 10 to 12 kc. Maximum duty <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">factor is about 0.6, decreasing with faster sweep rates.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">A slight alteration in this set-up will produce a double- <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">pulse generator. To do this, start with a B sweep rate that is<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">at least 5 times faster than the A sweep rate. Set DELAY<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">INTERVAL to about 5.00. Connect a 100 pf capacitor between <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">the center conductors of the A+ GATE OUT and DEL&#8217;D <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">TRIG OUT connectors on the rear of the instrument.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">The B + GATE OUT pulse will now occur twice during <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">each A sweep; the first beginning as A sweep begins and<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">the second begins at the end of the delay interval.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">The time separation between pulses is controlled by setting<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">DELAY INTERVAL. The minimum separation that can obtained <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">is a function of the Time Base B Generator hold-off time.<br \/>\n<\/span><\/p>\n<hr \/>\n<p><strong style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">*Output current must not exceed 2ma peak.<\/strong><\/p>\n<p><span style=\"font-family: 'times new roman', times, serif;\"><strong>Triggerable After Delay Interval<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Complex signals often contain a number of individual<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">events of different amplitudes. Since the trigger circuits <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">in the Type 565 are sensitive to signal amplitude, a stable <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">display will normally be obtained only when the sweep is<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">triggered by the event having the greatest amplitude.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">The TRIGGERABLE AFTER DELAY INTERVAL feature of the <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Type 565 provides a means of triggering the sweep by events <\/span><span style=\"font-family: 'times new roman', times, serif;\">other than those having the greatest amplitude. The following <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">instructions permit you to demonstrate that Time Base <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">\u2018B\u2019 can be triggered by virtually any event within a series <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">of events.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Set the controls and switches on the instrument as listed<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">except as follows:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Lower Beam INTENSITY\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0for normal display<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Time Base \u2018B\u2019 TRIGGER\u00a0 controls.\u00a0\u00a0\u00a0\u00a0\u00a0 some settings as Time <\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">controls Base \u2018A\u2019 TRIGGER<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Connect the CAL. OUT signal to both the Upper and Lower<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Beam vertical input connectors. Each beam should present<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">a square wave display.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Turn the DELAY INTERVAL dial about 2 turns in either<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">direction. Notice that both the Lower Beam display and<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">the brightened segment in the Upper Beam display, move<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">smoothly across the crt.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Set the DELAY INTERVAL dial so the brightened segment<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">in the Upper Beam display begins about in the middle of a<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">pulse top. Notice that the Lower Beam display also begins<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">in the middle of a pulse top. Now, set the \u2018B\u2019 MODE switch<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">to the TRIGGERABLE AFTER DELAY INTERVAL position.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Notice that the brightened segment in the Upper Beam<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">display has shifted to the next pulse on the right. The Lower<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Beam display now begins within the rising portion of the <\/span><span style=\"font-family: 'times new roman', times, serif;\">pulse.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Now turn the DELAY INTERVAL dial several full turns.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">The brightened segment in the Upper Beam display should<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">jump from one pulse to the next. In this demonstration,<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">the Lower Beam display appears unchanged because all<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">pulses are identical.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The display is produced in the following manner:<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Time Base \u2018B\u2019 produces one sweep for each \u2018A\u2019 sweep.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">\u2018B\u2019 sweep will begin at some time after the start of\u00a0 \u2018A\u2019<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">sweep. This time is the total of (1) the Time Base \u2018A\u2019 sweep<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">rate (TIME\/DIV.) multiplied by the DELAY INTERVAL dial <\/span><span style=\"font-family: 'times new roman', times, serif;\">setting, plus (2) the time between the end of this delay<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">interval and the next event in the signal which can trigger Time <\/span><span style=\"font-family: 'times new roman', times, serif;\">Base \u2018B\u2019.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">It is possible that Time Base \u2018B\u2019 might not be triggered<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">until long after Time Base \u2018A\u2019 has completed its sweep. If<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">separate triggering signals are being applied to the two time<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">bases, Time Base \u2018A\u2019 could produce several additional sweeps<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">before Time Base \u2018B\u2019 receives a triggering signal. Because<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">of this, the brightened trace segment could appear at any<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">point on the Upper Beam trace or might not appear at all.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>Delayed Trigger Output<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif;\">The delayed trigger output pulse is always available at <\/span><span style=\"font-family: 'times new roman', times, serif;\">the rear panel connector at the predetermined time during <\/span><span style=\"font-family: 'times new roman', times, serif;\">each sawtooth produced by Time Base \u2018A\u2019, regardless of the <\/span><span style=\"font-family: 'times new roman', times, serif;\">\u2018B\u2019 MODE switch setting. This output signal is discussed <\/span><span style=\"font-family: 'times new roman', times, serif;\">in greater detail under \u201cStarts After Delay lnterval\u201d, <\/span><span style=\"font-family: 'times new roman', times, serif;\">Demonstration 4.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>External Horizontal Inputs<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif;\">For special applications, you can deflect either beam <\/span><span style=\"font-family: 'times new roman', times, serif;\">horizontally with an externally derived signal. This permits <\/span><span style=\"font-family: 'times new roman', times, serif;\">you to use the oscilloscope to plot one function versus<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">another. The maximum bandpass of the horizontal amplifier<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">occurs at the fully clockwise setting of the EXT. HORIZ. GAIN <\/span><span style=\"font-family: 'times new roman', times, serif;\">control; dc to at least 350 kc.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">To use an external signal for horizontal deflection, <\/span><span style=\"font-family: 'times new roman', times, serif;\">connect the signal to either the Upper or Lower Beam EXT. <\/span><span style=\"font-family: 'times new roman', times, serif;\">HORIZ. IN connector. Place the appropriate horizontal <\/span><span style=\"font-family: 'times new roman', times, serif;\">display switch in the EXT. position. The horizontal deflection <\/span><span style=\"font-family: 'times new roman', times, serif;\">factors can be varied by adjusting the EXT. HORIZ GAIN<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">control such that a one volt peak-to-peak signal will produce <\/span><span style=\"font-family: 'times new roman', times, serif;\">from zero to at least 10 major graticule divisions of deflection.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The 10X MAG. switch has no effect when external horizontal <\/span><span style=\"font-family: 'times new roman', times, serif;\">deflection is used.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>Amplitude Calibrator<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif;\">The amplitude calibrator provides a convenient source <\/span><span style=\"font-family: 'times new roman', times, serif;\">of square waves of known amplitude at a frequency of <\/span><span style=\"font-family: 'times new roman', times, serif;\">approximately 1kc. The square waves are used primarily <\/span><span style=\"font-family: 'times new roman', times, serif;\">to adjust probe compensation and to verify the amplitude <\/span><span style=\"font-family: 'times new roman', times, serif;\">calibration of the oscilloscope vertical deflection systems.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Calibrator square waves are adjustable from 1 millivolt <\/span><span style=\"font-family: 'times new roman', times, serif;\">to 100 volts, peak-to-peak, in decade steps. The amplitude <\/span><span style=\"font-family: 'times new roman', times, serif;\">is controlled by the setting of the PEAK-TO-PEAK VOLTS <\/span><span style=\"font-family: 'times new roman', times, serif;\">switch. The output voltage is ac-curate within 3% of the PEAK- <\/span><span style=\"font-family: 'times new roman', times, serif;\">TO-PEAK VOLTS switch setting when the output is connected <\/span><span style=\"font-family: 'times new roman', times, serif;\">to a high-impedance load such as the INPUT connector of a <\/span><span style=\"font-family: 'times new roman', times, serif;\">vertical plug-in unit.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">When the .001, .01, .1 volt settings of the PEAK-TO-PEAK<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">VOLTS switch are used, it will be necessary to use a coax<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">cable to take the signal from the CAL. OUT connector. The<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">outer conductor of the cable must make good contact with<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">the shield portion of the CAL. OUT connector in order to<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">obtain an accurate output voltage.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 AUXILIARY FUNCTIONS<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>Intensity Modulation<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">The rear panel jacks marked UPPER BEAM CRT GRID and <\/span><span style=\"font-family: 'times new roman', times, serif;\">LOWER BEAM CRT GRID permit external signals to vary <\/span><span style=\"font-family: 'times new roman', times, serif;\">the intensity of the traces (Z-axis modulation). This feature <\/span><span style=\"font-family: 'times new roman', times, serif;\">can be used to refer oscilloscope time measurements to an <\/span><span style=\"font-family: 'times new roman', times, serif;\">external timing standard.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">In some applications, you may wish to use the VARIABLE<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">TIME\/DIV. control at an uncalibrated position to obtain a<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">sweep rate other than those provided by the TIME\/DIV.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">switch. Intensity modulation with time-marker pulses will<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">permit you to establish and monitor the desired sweep rate.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">This will eliminate the need for a separate vertical display of <\/span><span style=\"font-family: 'times new roman', times, serif;\">a time reference signal.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">Fast-rise pulses of short duration are usually used for<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">intensity modulation because they produce an easily<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">interpreted display. When other types of signals are used, it is <\/span><span style=\"font-family: 'times new roman', times, serif;\">important to note that sinewaves below 250 cycles will be<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">attenuated due to the ac signal coupling within the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">instrument. The signal amplitude required for visible trace<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">modulation depends upon the intensity level of the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">unmodulated trace.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>Trace Photography<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif;\">Several features of the Type 565 Oscilloscope are<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">particularly important when photographying\u00a0 the crt display. The <\/span><span style=\"font-family: 'times new roman', times, serif;\">rubber washers normally installed between the graticule <\/span><span style=\"font-family: 'times new roman', times, serif;\">and the bezel should be removed when either the light <\/span><span style=\"font-family: 'times new roman', times, serif;\">filter or a camera-mount bezel is installed. When a light <\/span><span style=\"font-family: 'times new roman', times, serif;\">filter is used, the graticule should be placed between it and <\/span><span style=\"font-family: 'times new roman', times, serif;\">the crt.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">There are two pairs of holes in the graticule for the scale<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">illumination pilot lamps. One pair is colored red and will<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">produce red graticule lines when aligned with the pilot lamps.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The second pair is clear and will produce white graticule<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">lines. White lines should be used whenever the light filter<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">is installed or when photographs are being taken. When the<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">trace is viewed without a light filter, the red lines are usually <\/span><span style=\"font-family: 'times new roman', times, serif;\">easier to see. In all cases, the side of the graticule that bears <\/span><span style=\"font-family: 'times new roman', times, serif;\">the scribed lines should be placed against the crt face.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The CONTRAST control, located inside the instrument at<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">the left side of the High Voltage Power Supply chassis, <\/span><span style=\"font-family: 'times new roman', times, serif;\">permits you to control the relative intensity of the intensified <\/span><span style=\"font-family: 'times new roman', times, serif;\">trace segment obtained in delayed sweep operation. This <\/span><span style=\"font-family: 'times new roman', times, serif;\">control is usually set fully clockwise (greatest contrast) for <\/span><span style=\"font-family: 'times new roman', times, serif;\">normal viewing. However, it may require resetting for less <\/span><span style=\"font-family: 'times new roman', times, serif;\">contrast while photographs are being taken so all portions of <\/span><span style=\"font-family: 'times new roman', times, serif;\">the picture will be properly exposed.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The CAMERA POWER jack, on the front panel, provides a<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">convenient power source for future camera accessories.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">The Single-Sweep feature, described previously in this<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\">section, is often used when non-repetitive waveforms are <\/span><span style=\"font-family: 'times new roman', times, serif;\">photographed.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif;\"><strong>Aux. Power Jack<br \/>\n<\/strong><\/span><span style=\"font-family: 'times new roman', times, serif;\">The auxiliary power jack on the rear panel is provided to<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">power future accessories for the Type 565, as well as other <\/span><span style=\"font-family: 'times new roman', times, serif;\">devices\u00bb.<\/span><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14281\" style=\"font-size: 1rem;\" src=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/T2.10-XF-Osc.Tek_.565.jpg\" alt=\"\" width=\"1500\" height=\"887\" srcset=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/T2.10-XF-Osc.Tek_.565.jpg 1500w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/T2.10-XF-Osc.Tek_.565-300x177.jpg 300w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/T2.10-XF-Osc.Tek_.565-768x454.jpg 768w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/T2.10-XF-Osc.Tek_.565-1024x606.jpg 1024w\" sizes=\"(max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><br \/>\n<span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">\u00a7\u00a7\u00a7<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Il testo prosegue nella sesta parte.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Per consultare le altre schede dedicate a questo oscilloscopio <span style=\"color: #800000;\">esposto al Museo MITI (su proposta di Fabio Panfili)<\/span>\u00a0scrivere \u201c565\u201d su Cerca.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\">Elaborazioni e testo a cura di Fabio Panfili.<br \/>\n<\/span><span style=\"font-family: 'times new roman', times, serif; font-size: 1rem;\"><span style=\"font-family: 'times new roman', times, serif;\"><span style=\"color: #008000;\">Per ingrandire le immagini cliccare su di esse col tasto destro del mouse e scegliere tra le opzioni.<\/span><\/span><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14284\" src=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1a-Osc.Tek_.565.jpg\" alt=\"\" width=\"1500\" height=\"862\" srcset=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1a-Osc.Tek_.565.jpg 1500w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1a-Osc.Tek_.565-300x172.jpg 300w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1a-Osc.Tek_.565-768x441.jpg 768w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1a-Osc.Tek_.565-1024x588.jpg 1024w\" sizes=\"(max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14285\" src=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1b-Osc.Tek_.565.jpg\" alt=\"\" width=\"1500\" height=\"936\" srcset=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1b-Osc.Tek_.565.jpg 1500w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1b-Osc.Tek_.565-300x187.jpg 300w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1b-Osc.Tek_.565-768x479.jpg 768w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment1b-Osc.Tek_.565-1024x639.jpg 1024w\" sizes=\"(max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14286\" src=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2a-Osc.Tek_.565.jpg\" alt=\"\" width=\"1620\" height=\"954\" srcset=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2a-Osc.Tek_.565.jpg 1620w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2a-Osc.Tek_.565-300x177.jpg 300w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2a-Osc.Tek_.565-768x452.jpg 768w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2a-Osc.Tek_.565-1024x603.jpg 1024w\" sizes=\"(max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14287\" src=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2b-Osc.Tek_.565.jpg\" alt=\"\" width=\"1500\" height=\"870\" srcset=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2b-Osc.Tek_.565.jpg 1500w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2b-Osc.Tek_.565-300x174.jpg 300w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2b-Osc.Tek_.565-768x445.jpg 768w, https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-content\/uploads\/2019\/11\/7calibration-adjustment2b-Osc.Tek_.565-1024x594.jpg 1024w\" sizes=\"(max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><br \/>\n<\/span><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Oscilloscopio Tektronix Type 565. Quinta parte. Nell\u2019inventario D del 1956 si trova al n\u00b0 3747 e risulta acquistato nell\u2019agosto del 1964; vi si legge: \u201cSilvestar ltd. Milano. Oscilloscopio Tektronix mod. 565 matr. 689. Dest. Elettronica \u20a4 1\u0387678\u0387600\u201d. Insieme alla fotocamera che \u00e8 al n\u00b0 3746, dove si legge: \u201cSilvestar ltd. Milano. Macchina fotografica Tektronix mod. &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/oscilloscope-tektronix-type-565-serial-689-seventh-part\/\" class=\"more-link\">Leggi tutto<span class=\"screen-reader-text\"> &#8220;Oscilloscope Tektronix Type 565 serial 689, fifth part ( MITI Muesum)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0,"footnotes":""},"categories":[7],"tags":[],"_links":{"self":[{"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/posts\/14280"}],"collection":[{"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/comments?post=14280"}],"version-history":[{"count":4,"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/posts\/14280\/revisions"}],"predecessor-version":[{"id":25531,"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/posts\/14280\/revisions\/25531"}],"wp:attachment":[{"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/media?parent=14280"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/categories?post=14280"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.istitutomontani.edu.it\/museovirtuale\/wp-json\/wp\/v2\/tags?post=14280"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}